HAPSITE® ER Chemical Identification System
The Only Person-Portable GC/MS That Identifies VOCs and SVOCs
Quick, Easy, Accurate On-Site Performance
HAPSITE ER is the only person-portable Gas Chromatograph/Mass Spectrometer (GC/MS) that requires minimal training to deliver qualitative and quantitative lab-quality results-in the field, in less than 10 minutes. In fact, all the operator has to do is push a button to begin identifying and quantifying volatile organic compounds (VOCs), toxic industrial chemicals (TICs), toxic industrial materials (TIMs), chemical warfare agents (CWAs), and select semi-volatile organic compounds (SVOCs).
HAPSITE ER has the capability to identify analytes in the PPM (parts per million) – PPT (parts per trillion) range. The GC column provides sharp chromatography and excellent resolution. During the quantitation method, the front panel clearly displays what chemicals are present, their concentration, and access to information regarding the degree of danger – to help make quick decisions affecting life, health, and safety.
Maximize the power of HAPSITE ER with the following accessories:
Features
Fast, confirmatory results in the field directly comparable to laboratory GC/MS data
Universal interface allows for accessory expansion without a hardware change to HAPSITE
Simple operation for even basic skill levels with minimal training
Visual confirmation of correct probe placement for optimum sample collection
Clear, color indicators of sample identity and level of danger
Pre-programmed methods to obtain quality data in minutes with a few simple keystrokes
Bright, graphical display of chromatograms, spectra, and instrument status for easy viewing
Built-in GPS records exact sampling location for legally defensible data
Specifications
Type
HAPSITE ER
Operating Temperature
°C °F
5 to 45
L x W x H
in. cm
18 x 17 x 7
Weight (with battery)
lb. kg
42
Power Supply
Rechargeable NiMH battery pack or AC converter
Battery Life
h
2-3
Power Requirement
V (dc) Watt
24
Hard Drive
GB
16 Solid State Flash Drive
Flash Drive
USB
Display
in.
6.5 VGA color display with touch screen
Sample Introduction
Air probe (included) or optional accessory
Carrier Gas
Nitrogen
Data System
Intel® Pentium® processor
Communication
802.11G wireless or direct Ethernet connection
Data Analysis
AMDIS Mass Spectral Libraries, NIOSH, (NIST on optional laptop)
Sample Type
VOCs and select SVOCs
Detection Limit
PPT for most analytes
Mass Spectrometer
Mass Range
amu
41-300 (1-300 using SIM)
Scan Rate
1000 AMU/sec @ 10 points per AMU
Ionization Mode
eV
70
Detector
Electron Multiplier
Vacuum System
Non Evaporable Getter (NEG) Pump
Dynamic Range
decades
7
Gas Chromatograph
GC Column
15 m, db-1MS, 0.25 mm i.d., 1.0 um df (standard)
Temperature Range
°C °F
45-200
Consumables
HAPSITE ER
Part Number
Description
070-860-2
HAPSITE ER Training Kit, XINF-19-KIT
930-242-G1
NEG Pump, factory installed
930-477-P1
Gas Combo Pack
930-705-G1
Sample Loop Kit
930-425-P1
Spare Non Evaporable Getter (NEG) Pump
930-205-G1
Ionizer w/Magnet, Hapsite Smart Plus
930-4062-G1
Hapsite Battery
930-432-P6
Canister, Carrier Gas, 6 each
930-432-P12
Canister, Carrier Gas, 12 each
930-433-P6
Canister, Internal Standard, 6 each
930-433-P12
Canister, Internal Standard, 12 each
930-432-P24
Canister, Carrier Gas, 24 each
930-730-G1
Extended Life Carrier Gas Deployment Kit
930-4611-P1
Extended Life Carrier Gas
930-716-G1
Concentrator, Tri-Bed Kit
930-251-G1
Concentrator, Tenax Kit
930-249-G2
Concentrator Cover
930-0221-G1
Concentrator Tube Nut and Ferrule Kit
930-250-G1
Sample Loop Cover
071-747
Performance Standard Concentrator / Air
071-748
Chemical Kit, Performance/IS
071-760
Chemical Standards Kit, HAPSITE
070-1686
Sample Bag, 1 Liter, ALTEF, 10 pack
070-1419
Sample Bag, Vacu-Tube, 0.7 Liter,10 each
070-1224
Gastight Syringe 50 mL, w/Luer Lock
070-1205
Gastight Syringe, 25 mL
070-1206
Gastight Syringe, 10 μl
070-1207
Replacement Needle, 10 μl
070-1223
10 μl Syringe, 6 pack
070-1420
Vacu-Tube, 0.7 Liter
070-1454
Syringe, 1L, w/Luer Lock
Spare Parts
HAPSITE ER
Part Number
Description
930-261-G71
Replacement Ruggedized Laptop Computer
074-5009-G1
User Guide CD, HAPSITE ER
930-035-G1
HAPSITE Smart IQ Software, V1.30
930-0351-G1
HAPSITE ER IQ Software
930-0351-G21
HAPSITE Smart Plus Software
930-4071-G1
NIST Software Version Upgrade
930-4081-G1
NIST Software, w/AMDIS
600-1319-P2
Ethernet Communication Cable
930-206-G6
Hand Control Unit, HAPSITE ER
930-206-G7
Hand Control Unit, Blue, HAPSITE ER
930-0231-G1
Probe Nut and Ferrule Kit, 5 each
070-1545
Pipe Insulation, 5/8 ID, 1/2 Thick, Slit
930-705-G1
Sample Loop Kit
930-250-G1
Sample Loop Cover
930-469-P1
110V(ac) Power Supply, United States
930-469-P2
230V(ac) Power Supply, Europe
930-469-G4
230V(ac) Power Supply, Australia / China
930-470-G1
Battery Charger
068-002
Power Cord – 115V
068-0388
Power Cord 220 V UK Plug
068-0393
Power Cord 220 V China/Australia Plug
930-246-G1
Hot Swap Cable
930-489-G1
Gas Chromatograph Column, 30 m
934-430-G2
Gas Chromatograph Column, 15 m
930-464-P1
Hapsite Shipping Case
930-4131-P1
HAPSITE Accessory Shipping Case
930-4551-G1
Backpack, HAPSPACK
930-4051-P1
Cold Weather Insulation Bag
059-329
use 059-0329 Quick disconnect with valve
930-022-G1
Tool Kit with Torque Wrench
930-0211-G1
Torque Wrench
930-021-G1
Gasket Kit
930-2020-G2
Decon Cap Plug Kit, HAPSITE ER
930-612-P1
USB Drive
930-261-G61
Replacement Standard Laptop Computer
930-465-P1
Shipping case, Service Module
Brochures
Manuals
Catalogs
Other Files